Am J Infect Control ; 49(12): 1506-1510, 2021 12.
Article in English | MEDLINE | ID: covidwho-1351429

ABSTRACT

BACKGROUND: Ambulatory clinics attend to COVID-19 patients, often in spaces with less than ideal ventilation. Testing and treatments can often include aerosol-generating procedures. Portable high efficiency particulate air (HEPA) filtration units have been used to remove airborne contaminants in these areas. METHODS: A particle counter was used to evaluate the effectiveness of portable HEPA filtration units when a proxy airborne contaminant (powder) was actuated into the air. The Center for Disease Control and Prevention's (CDC) Airborne Contaminant Removal table served as a basis for initial particle readings at 6 minutes. RESULTS: Percent decrease was calculated post powder actuation at the 6-minute and 12-minute mark. There was a statistically significant decrease in smaller particles at the 6-minute and 12-minute mark when the HEPA filtration units were used. CONCLUSION: As an adjunct infection control intervention, portable HEPA filtration units can make outpatient exam rooms safer for patients and staff by decreasing cumulative airborne particles.


Subject(s)
Air Pollution, Indoor , COVID-19 , Aerosols , Filtration , Humans , Infection Control , SARS-CoV-2 , Ventilation